Screw compressor service room placing and installation issue

After the air compressor has been selected and purchased, it cannot be directly turned on. It must be installed and debugged before it can be put into normal use. Due to the limitations of the venue and other conditions, many air compressors are randomly placed and installed, as long as it fits. In fact, the placement and installation of air compressors is also important. A good placement and installation position can improve the performance and life of the air compressor.

 

Screw compressor service room,Screw compressor installation issue

1.The vibration generated when the screw air compressor is running is small, so no special fixed parts are needed, but the floor should be flat, and the ground should be enough to bear the weight of the compressor. to prevent the screw air compressor from vibrating and causing noise.

 

2.If the screw air compressor is installed on the upper floor, anti-vibration measures shall be taken to prevent vibration from being transmitted to the downstairs, or resonance may cause damage to the air compressor and the building, thus reducing safety hazards.

3.Due to the large amount of heat dissipated by the screw air compressor, both air-cooled and water-cooled models require a good ventilation environment. If the ambient temperature is too high, the compressor may experience high temperature operation or over-temperature shutdown. However, it cannot be placed in the open air. Sun exposure and rain are not conducive to the use of air compressors, reducing the service life of the machine.

Screw compressor service room,Screw compressor installation issue

Several ventilation methods are as follows:

A: The air inlet and the air outlet are placed on the outdoor wall, which is called free installation;

B: increase the exhaust fan;

C: Install the air duct to exhaust the air outside the wall;

D: design of the air duct with the guide plate;

(If necessary, the hot air can be transported into the cold machine room to avoid the cold junction of the components when the temperature is below zero Celsius)

E: The hot air discharged from the machine is used as a warm air.

In the cold winter, you can use the hot air of the machine to increase the indoor temperature, and in the summer you can discharge the hot air outside.